High quality dry type transformer manufacturer

Best rated transformer core cutting machine manufacturer: When these harmonic currents flow through a transformer, they can cause increased core losses due to hysteresis and eddy currents. Hysteresis loss is related to the magnetization and demagnetization of the transformer’s core material in response to the alternating current. Eddy current loss occurs when induced currents circulate within the core material, creating local magnetic fields that oppose the main field. Both these losses increase with the frequency of the current. Thus, higher frequency harmonic currents can lead to considerably higher core losses, reducing the transformer’s efficiency and causing it to overheat, which can shorten its lifespan. Find even more details at https://www.canwindg.com/products-detail-129320.

The cut to length line is a special equipment for the production of transformer core, is our latest generation of cross shear line. This cut to length production line is used for shearing, O punching and V notch of transformer core sheet. The special point of this ctl line is that two O punch and one V notch can work at the same time to produce transformer core pieces with 3, 5, 7 steps in vertical direction and 3, 5, 7 steps in horizontal direction.

A transformer coil winding machine is an intricate piece of machinery with an essential role in the manufacturing of transformers, combining modern technology and meticulousness to create high-quality products efficiently. The process starts with the feeding of copper wire into the machine, which passes through a line-up of calibrations guides and tensioners designed to secure alignment and prevent damage. An automated system then causes rotation, gradually looping copper wire around the transformer coil. A computerized system oversees variables such as speed, pitch control, layer count and insulation thickness for consistent turns. Moreover, for distinct transformer models or designs, these machines can be fitted with extra features such as automatic lead cutting and tapping mechanisms for increased versatility and productivity.

What is the capacity of the transformer related to? The capacity of the transformer refers to the maximum load electric power that the transformer can bear. The capacity of the transformer is related to the following factors: Input voltage and output voltage: The input voltage and output voltage of the transformer determine the transformation ratio of the transformer, which affects the capacity of the transformer. The higher the input voltage of the transformer and the lower the output voltage, the larger the transformation ratio and the larger the capacity. Load nature: Different loads have different power factors, harmonic content and other characteristics, which affect the capacity of the transformer. For inductive loads, the capacity of the transformer can be appropriately reduced; for nonlinear loads, the capacity of the transformer needs to be appropriately increased.

Epoxy resin is non – combustible, flame retardant, self – extinguishing solid insulation material, safe and clean. It is also a solid insulation material with proven insulation and heat dissipation technology for more than 40 years.Epoxy resin products can be used for dry type transformer, for insulation parts, for instrument transformer, for electrical composite parts and for room temperature curing. Epoxy resin dry transformer uses epoxy resin as insulation material. The high and low voltage windings are made of copper tape (foil), industrial epoxy resin is poured in vacuum and cured, forming a high strength FRP body structure. Insulation grade F, H. Epoxy resin dry transformer has the characteristics of good electrical performance, strong resistance to lightning impact, strong resistance to short circuit, small size and light weight. Temperature display controller can be installed to display and control the operating temperature of the transformer winding to ensure the normal service life of the transformer.

Independently developed a series of high -speed cut to length line which up to 128 pcs/mins, which increased the cutting speed 2-3 times Independently developed the bridge automatic cutting and automatic lamination cut to length line, which can realize 20 large transformer core column level for automatic lamination, this project has won the record and nomination of Guangdong major research and development projects; Participated in the application and filing of the major science and technology special project of intelligent robot and equipment manufacturing”in the research and development plan of key fields in Guangdong province in 2018-2019. The company has been constantly extending the innovation chain around the guiding ideology of industrial chain deploy innovation chain.

The manufacturing technology and product quality of electrical steel plate is one of the important signs to measure the development level of special steel production and science and technology in a country. At present, the quantity, quality and specification of cold rolled electrical steel in China cannot meet the needs of energy (power) industry development, and there is a big gap between China and Japan in terms of production technology, equipment, management and scientific research.Canwin is one of the most professional silicon steel sheet suppliers in China, which has been specialized in silicon steel manufacturing for over 20 years.Contact us, we are the best choice. Find extra information at canwindg.com

The main pillar of the smart grid is the smart substation, which is not only an important hub for power transmission and distribution, but also directly affects the operational and monitoring capabilities of the smart grid through its operational safety and stability. Through the network, information can be exchanged, and the transformer can share information with the process layer and the station control layer. On the premise of ensuring product performance, the integration of monitoring, control, measurement, protection, and metering is designed to achieve the integration of transformer components with actuators, sensors, and transformers.

Connection group label: According to the phase relationship between the primary and secondary windings of the transformer, the transformer windings are connected into various combinations, which are called the connection group of the windings. In order to distinguish different connection groups, the clock notation is often used, that is, the phasor of the line voltage on the high-voltage side is used as the long hand of the clock, fixed at 12, and the phasor of the line voltage on the low-voltage side is used as the short hand of the clock. The number of the short hand indicates the connection group label. For example, Dyn11 indicates that the primary winding is (triangle) connected, and the secondary winding is (star) connected with a center point, and the group number is (11) points.

What are the consequences of parallel operation of transformers that do not meet the parallel operation conditions? Parallel operation of transformers that do not meet the parallel operation conditions may lead to the following consequences: Voltage instability: Different transformers may have different electrical parameters, such as transformation ratio, resistance, inductance, etc. If these transformers with different parameters are forced to run in parallel, the overall electrical parameters after paralleling may be unstable, thereby affecting the quality of power supply. Uneven load distribution: If the transformers with uneven load distribution are forced to run in parallel, different transformers may bear different loads, thus affecting the service life and stability of the transformers. Excessive temperature rise: If different transformers are operated in parallel, their heat dissipation conditions and methods may be different, which may cause excessive temperature rise of some transformers, and may even damage the transformer.

Oil immersed transformers are the most commonly used equipment mainly because of their simple structure and reliable operation. It has faster heat dissipation, uniform conduction, and better insulation performance than the dry-type transformer.Oil transformers are used in power distribution or electrical substations. Their transformer core and coils are immersed in oil, which cools and insulates. Oil circulates through ducts in the coil and around the coil and core assembly, moved by convection.

Categories